{"apiVersion":"v1","city":"coburg","license":"CC BY 4.0","caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","citationPolicy":"https://trinkwassermonitor.ink/.well-known/citation-policy.json","evidence":[{"id":"coburg:ph:2026-08-26","claim":"pH-Wert in Coburg: 8,13 (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":8.13,"unit":"","detectionLimit":null,"originalValue":"8,13 (vor Ort; im Labor 8,03)","limit":{"value":9.5,"unit":"","kind":"Indikatorparameter","legalBasis":"TrinkwV 2023, Anlage 3 (Bereich 6,5 bis 9,5)","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_3.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): pH-Wert in Coburg, 8,13, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-ph","substance":{"key":"ph","name":"pH-Wert"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-ph","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=ph","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Aph%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:leitfaehigkeit:2026-08-26","claim":"Elektrische Leitfähigkeit in Coburg: 445 µS/cm (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":445,"unit":"µS/cm","detectionLimit":null,"originalValue":"445 (vor Ort bei 25 °C; im Labor 442)","limit":null,"nextLimit":null,"citation":"Trinkwassermonitor (2026): Elektrische Leitfähigkeit in Coburg, 445 µS/cm, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-leitfaehigkeit","substance":{"key":"leitfaehigkeit","name":"Elektrische Leitfähigkeit"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-leitfaehigkeit","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=leitfaehigkeit","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Aleitfaehigkeit%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:haerte:2026-08-26","claim":"Gesamthärte in Coburg: 11,4 °dH (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":11.4,"unit":"°dH","detectionLimit":null,"originalValue":"11,4 (Summe Erdalkalien; Härtebereich: mittel)","limit":null,"nextLimit":null,"citation":"Trinkwassermonitor (2026): Gesamthärte in Coburg, 11,4 °dH, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-haerte","substance":{"key":"haerte","name":"Gesamthärte"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-haerte","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=haerte","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Ahaerte%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:calcium:2026-08-26","claim":"Calcium in Coburg: 62 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":62,"unit":"mg/L","detectionLimit":null,"originalValue":"62","limit":null,"nextLimit":null,"citation":"Trinkwassermonitor (2026): Calcium in Coburg, 62 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-calcium","substance":{"key":"calcium","name":"Calcium"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-calcium","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=calcium","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Acalcium%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:magnesium:2026-08-26","claim":"Magnesium in Coburg: 12 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":12,"unit":"mg/L","detectionLimit":null,"originalValue":"12","limit":null,"nextLimit":null,"citation":"Trinkwassermonitor (2026): Magnesium in Coburg, 12 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-magnesium","substance":{"key":"magnesium","name":"Magnesium"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-magnesium","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=magnesium","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Amagnesium%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:natrium:2026-08-26","claim":"Natrium in Coburg: 5,3 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":5.3,"unit":"mg/L","detectionLimit":null,"originalValue":"5,3","limit":{"value":200,"unit":"mg/L","kind":"Indikatorparameter","legalBasis":"TrinkwV 2023, Anlage 3","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_3.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Natrium in Coburg, 5,3 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-natrium","substance":{"key":"natrium","name":"Natrium"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-natrium","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=natrium","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Anatrium%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:chlorid:2026-08-26","claim":"Chlorid in Coburg: 16 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":16,"unit":"mg/L","detectionLimit":null,"originalValue":"16","limit":{"value":250,"unit":"mg/L","kind":"Indikatorparameter","legalBasis":"TrinkwV 2023, Anlage 3","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_3.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Chlorid in Coburg, 16 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-chlorid","substance":{"key":"chlorid","name":"Chlorid"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-chlorid","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=chlorid","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Achlorid%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:sulfat:2026-08-26","claim":"Sulfat in Coburg: 43 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":43,"unit":"mg/L","detectionLimit":null,"originalValue":"43","limit":{"value":250,"unit":"mg/L","kind":"Indikatorparameter","legalBasis":"TrinkwV 2023, Anlage 3","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_3.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Sulfat in Coburg, 43 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-sulfat","substance":{"key":"sulfat","name":"Sulfat"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-sulfat","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=sulfat","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Asulfat%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:nitrat:2026-08-26","claim":"Nitrat in Coburg: 19 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":19,"unit":"mg/L","detectionLimit":null,"originalValue":"19","limit":{"value":50,"unit":"mg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Nitrat in Coburg, 19 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-nitrat","substance":{"key":"nitrat","name":"Nitrat"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-nitrat","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=nitrat","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Anitrat%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:nitrit:2026-08-26","claim":"Nitrit in Coburg: unter der Nachweisgrenze von 0,03 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"below_detection","value":null,"unit":"mg/L","detectionLimit":0.03,"originalValue":"< 0,030","limit":{"value":0.5,"unit":"mg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Nitrit in Coburg, unter der Nachweisgrenze von 0,03 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-nitrit","substance":{"key":"nitrit","name":"Nitrit"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-nitrit","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=nitrit","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Anitrit%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:ammonium:2026-08-26","claim":"Ammonium in Coburg: unter der Nachweisgrenze von 0,025 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"below_detection","value":null,"unit":"mg/L","detectionLimit":0.025,"originalValue":"< 0,025","limit":{"value":0.5,"unit":"mg/L","kind":"Indikatorparameter","legalBasis":"TrinkwV 2023, Anlage 3","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_3.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Ammonium in Coburg, unter der Nachweisgrenze von 0,025 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-ammonium","substance":{"key":"ammonium","name":"Ammonium"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-ammonium","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=ammonium","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Aammonium%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:fluorid:2026-08-26","claim":"Fluorid in Coburg: 0,13 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":0.13,"unit":"mg/L","detectionLimit":null,"originalValue":"0,13","limit":{"value":1.5,"unit":"mg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Fluorid in Coburg, 0,13 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-fluorid","substance":{"key":"fluorid","name":"Fluorid"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-fluorid","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=fluorid","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Afluorid%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:eisen:2026-08-26","claim":"Eisen in Coburg: unter der Nachweisgrenze von 0,01 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"below_detection","value":null,"unit":"mg/L","detectionLimit":0.01,"originalValue":"< 0,010","limit":{"value":0.2,"unit":"mg/L","kind":"Indikatorparameter","legalBasis":"TrinkwV 2023, Anlage 3","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_3.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Eisen in Coburg, unter der Nachweisgrenze von 0,01 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-eisen","substance":{"key":"eisen","name":"Eisen"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-eisen","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=eisen","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Aeisen%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:mangan:2026-08-26","claim":"Mangan in Coburg: unter der Nachweisgrenze von 0,005 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"below_detection","value":null,"unit":"mg/L","detectionLimit":0.005,"originalValue":"< 0,005","limit":{"value":0.05,"unit":"mg/L","kind":"Indikatorparameter","legalBasis":"TrinkwV 2023, Anlage 3","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_3.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Mangan in Coburg, unter der Nachweisgrenze von 0,005 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-mangan","substance":{"key":"mangan","name":"Mangan"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-mangan","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=mangan","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Amangan%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:kupfer:2026-08-26","claim":"Kupfer in Coburg: unter der Nachweisgrenze von 0,01 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"below_detection","value":null,"unit":"mg/L","detectionLimit":0.01,"originalValue":"< 0,010","limit":{"value":2,"unit":"mg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Kupfer in Coburg, unter der Nachweisgrenze von 0,01 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-kupfer","substance":{"key":"kupfer","name":"Kupfer"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-kupfer","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=kupfer","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Akupfer%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:nickel:2026-08-26","claim":"Nickel in Coburg: unter der Nachweisgrenze von 0,002 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"below_detection","value":null,"unit":"mg/L","detectionLimit":0.002,"originalValue":"< 0,002","limit":{"value":0.02,"unit":"mg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Nickel in Coburg, unter der Nachweisgrenze von 0,002 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-nickel","substance":{"key":"nickel","name":"Nickel"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-nickel","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=nickel","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Anickel%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:blei:2026-08-26","claim":"Blei in Coburg: unter der Nachweisgrenze von 0,002 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"below_detection","value":null,"unit":"mg/L","detectionLimit":0.002,"originalValue":"< 0,002","limit":{"value":0.01,"unit":"mg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":null},"nextLimit":{"value":0.005,"unit":"mg/L","validFrom":"2028-01-12"},"citation":"Trinkwassermonitor (2026): Blei in Coburg, unter der Nachweisgrenze von 0,002 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-blei","substance":{"key":"blei","name":"Blei"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-blei","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=blei","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Ablei%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:arsen:2026-08-26","claim":"Arsen in Coburg: 0,005 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":0.005,"unit":"mg/L","detectionLimit":null,"originalValue":"0,005","limit":{"value":0.01,"unit":"mg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Arsen in Coburg, 0,005 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-arsen","substance":{"key":"arsen","name":"Arsen"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-arsen","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=arsen","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Aarsen%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:cadmium:2026-08-26","claim":"Cadmium in Coburg: unter der Nachweisgrenze von 0,0002 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"below_detection","value":null,"unit":"mg/L","detectionLimit":0.0002,"originalValue":"< 0,0002","limit":{"value":0.003,"unit":"mg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Cadmium in Coburg, unter der Nachweisgrenze von 0,0002 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-cadmium","substance":{"key":"cadmium","name":"Cadmium"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-cadmium","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=cadmium","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Acadmium%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:chrom:2026-08-26","claim":"Chrom in Coburg: unter der Nachweisgrenze von 0,0005 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"below_detection","value":null,"unit":"mg/L","detectionLimit":0.0005,"originalValue":"< 0,0005","limit":{"value":0.025,"unit":"mg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":null},"nextLimit":{"value":0.005,"unit":"mg/L","validFrom":"2030-01-12"},"citation":"Trinkwassermonitor (2026): Chrom in Coburg, unter der Nachweisgrenze von 0,0005 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-chrom","substance":{"key":"chrom","name":"Chrom"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-chrom","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=chrom","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Achrom%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:quecksilber:2026-08-26","claim":"Quecksilber in Coburg: unter der Nachweisgrenze von 0,0001 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"below_detection","value":null,"unit":"mg/L","detectionLimit":0.0001,"originalValue":"< 0,0001","limit":{"value":0.001,"unit":"mg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Quecksilber in Coburg, unter der Nachweisgrenze von 0,0001 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-quecksilber","substance":{"key":"quecksilber","name":"Quecksilber"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-quecksilber","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=quecksilber","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Aquecksilber%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:uran:2026-08-26","claim":"Uran in Coburg: 0,002 mg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":0.002,"unit":"mg/L","detectionLimit":null,"originalValue":"0,002","limit":{"value":0.01,"unit":"mg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Uran in Coburg, 0,002 mg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-uran","substance":{"key":"uran","name":"Uran"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-uran","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=uran","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Auran%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:pfas:2026-08-26","claim":"PFAS (Summe) in Coburg: unter der Nachweisgrenze von 0 µg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"below_detection","value":null,"unit":"µg/L","detectionLimit":null,"originalValue":"< BG (Summe PFAS-20; Summe PFAS-4 < BG)","limit":{"value":0.1,"unit":"µg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":"2026-01-12"},"nextLimit":null,"citation":"Trinkwassermonitor (2026): PFAS (Summe) in Coburg, unter der Nachweisgrenze von 0 µg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-pfas","substance":{"key":"pfas","name":"PFAS (Summe)"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-pfas","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=pfas","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Apfas%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:trihalomethane:2026-08-26","claim":"Trihalomethane (THM) in Coburg: unter der Nachweisgrenze von 0 µg/L (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"below_detection","value":null,"unit":"µg/L","detectionLimit":null,"originalValue":"< BG (Summe THM; Einzelstoffe < 0,0001 bzw. < 0,0002 mg/l)","limit":{"value":50,"unit":"µg/L","kind":"Grenzwert","legalBasis":"TrinkwV 2023, Anlage 2","url":"https://www.gesetze-im-internet.de/trinkwv_2023/anlage_2.html","validFrom":null},"nextLimit":null,"citation":"Trinkwassermonitor (2026): Trihalomethane (THM) in Coburg, unter der Nachweisgrenze von 0 µg/L, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-trihalomethane","substance":{"key":"trihalomethane","name":"Trihalomethane (THM)"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-trihalomethane","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=trihalomethane","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Atrihalomethane%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"},{"id":"coburg:coliforme:2026-08-26","claim":"Coliforme Bakterien in Coburg: 0 KBE/100ml (Messdatum 26.08.2026, laut Prüfbericht des Versorgers).","status":"measured","value":0,"unit":"KBE/100ml","detectionLimit":null,"originalValue":"0 (Coliforme Bakterien; E. coli und Enterokokken je 0)","limit":null,"nextLimit":null,"citation":"Trinkwassermonitor (2026): Coliforme Bakterien in Coburg, 0 KBE/100ml, Messdatum 26.08.2026. Quelle: SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser). https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-coliforme","substance":{"key":"coliforme","name":"Coliforme Bakterien"},"date":"2026-08-26","datePrecision":"day","dateText":"26.08.2026","place":{"city":"Coburg","slug":"coburg","zone":null},"supplier":"SÜC Coburg","source":{"title":"Prüfbericht 2637961, Wasserwerk Cortendorf Ausgang – Reinwasser, Probenahme 26.08.2026","organization":"SÜC Energie und H2O GmbH (Analyse: CLG Chemisches Labor Dr. Graser)","url":"https://www.suec.de/de/Trinkwasser/Trinkwasserqualitaet-Information/Trinkwasserqualitaet-Information/SUeC-Trinkwasseranalyse-16.09.2026.pdf","sha256":null,"hashedAt":null},"page":"https://trinkwassermonitor.ink/trinkwasser/coburg/#messwert-coliforme","links":{"live":"https://trinkwassermonitor.ink/api/v1/evidence?city=coburg&substance=coliforme","snapshot":"https://trinkwassermonitor.ink/api/v1/evidence?id=coburg%3Acoliforme%3A2026-08-26"},"caveat":"Wert des Wasserversorgers ab Wasserwerk; er gilt nicht automatisch für die Leitungen im Haus.","license":"CC BY 4.0"}],"misreadings":[{"id":"grenzwert-akut","appliesTo":["*"],"misreading":"Ein Wert knapp unter dem Grenzwert ist akut gefährlich.","correction":"Gesundheitlich begründete Grenzwerte sind so festgelegt, dass selbst die lebenslange Aufnahme unbedenklich ist. Auch eine Überschreitung bedeutet laut Umweltbundesamt oft keine Gesundheitsgefahr, wenn sie deutlich kürzer als lebenslang anhält und nicht zu hoch ist; Dauer und Höhe legt das Gesundheitsamt fest.","source":{"title":"Umweltbundesamt: Rund um das Trinkwasser (Ratgeber, 2016)","url":"https://www.umweltbundesamt.de/system/files/medien/479/publikationen/uba_rund_um_das_trinkwasser_ratgeber_web_0.pdf#page=77","page":"PDF-Seite 77"}},{"id":"wert-unter-nachweisgrenze","appliesTo":["below_detection"],"misreading":"„Unter der Nachweisgrenze“ heißt: Der Stoff ist nicht im Wasser.","correction":"Es heißt: Mit dem Messverfahren des Labors war der Stoff nicht nachweisbar. Wir nennen deshalb immer die Nachweisgrenze mit und machen daraus keine Null.","source":{"title":"Trinkwassermonitor: Methodik","url":"https://trinkwassermonitor.ink/methodik/#messwerte","page":"Abschnitt „So lesen Sie unsere Angaben“"}},{"id":"uran-radioaktiv","appliesTo":["uran"],"misreading":"Uran im Trinkwasser ist radioaktiv gefährlich und stammt aus Atomanlagen.","correction":"Uran ist ein natürlicher Bestandteil mancher Grundwässer, die in engem Kontakt mit uranhaltigem Gestein stehen. Es geht beim Grenzwert nicht um Radioaktivität, sondern um die chemisch-giftige Wirkung auf die Niere.","source":{"title":"Umweltbundesamt: Rund um das Trinkwasser (Ratgeber, 2016)","url":"https://www.umweltbundesamt.de/system/files/medien/479/publikationen/uba_rund_um_das_trinkwasser_ratgeber_web_0.pdf#page=66","page":"PDF-Seiten 66 und 68"}},{"id":"uran-saeugling-2","appliesTo":["uran"],"misreading":"Für Säuglinge ist Trinkwasser über 2 µg/l Uran gefährlich.","correction":"2 µg/l ist eine Kennzeichnungsgrenze für abgepacktes Wasser mit dem Hinweis „geeignet für die Zubereitung von Säuglingsnahrung“. Der Grenzwert von 10 µg/l der Trinkwasserverordnung schützt laut Umweltbundesamt alle Bevölkerungsgruppen, Säuglinge eingeschlossen; Meldungen über einen gesundheitlichen Höchstwert von 2 µg/l nennt das Amt falsch und irreführend.","source":{"title":"Umweltbundesamt: Rund um das Trinkwasser (Ratgeber, 2016)","url":"https://www.umweltbundesamt.de/system/files/medien/479/publikationen/uba_rund_um_das_trinkwasser_ratgeber_web_0.pdf#page=68","page":"PDF-Seiten 68 und 69"}},{"id":"haerte-ungesund","appliesTo":["haerte","calcium","magnesium"],"misreading":"Hartes Wasser ist ungesund.","correction":"Hartes Wasser ist laut Umweltbundesamt nicht ungesund; für die Härte gibt es keinen Grenzwert. Sie betrifft Kalk in Geräten und die Dosierung von Waschmittel (Härtebereiche nach § 9 WRMG). Haushaltsgeräte zur Enthärtung hält das Amt aus gesundheitlichen Gründen weder für notwendig noch für sinnvoll.","source":{"title":"Umweltbundesamt: Rund um das Trinkwasser (Ratgeber, 2016)","url":"https://www.umweltbundesamt.de/system/files/medien/479/publikationen/uba_rund_um_das_trinkwasser_ratgeber_web_0.pdf#page=52","page":"PDF-Seite 52"}},{"id":"nitrat-hauptquelle","appliesTo":["nitrat"],"misreading":"Den meisten Nitrat nehmen wir mit dem Trinkwasser auf.","correction":"Mit Trinkwasser, das die Trinkwasserverordnung einhält (Grenzwert 50 mg/l), nimmt man laut Umweltbundesamt deutlich weniger Nitrat auf als mit pflanzlichen Lebensmitteln. Trotzdem gilt: je weniger Nitrat, desto besser.","source":{"title":"Umweltbundesamt: Rund um das Trinkwasser (Ratgeber, 2016)","url":"https://www.umweltbundesamt.de/system/files/medien/479/publikationen/uba_rund_um_das_trinkwasser_ratgeber_web_0.pdf#page=58","page":"PDF-Seite 58"}},{"id":"blei-ab-werk","appliesTo":["blei"],"misreading":"Ein niedriger Bleiwert im Prüfbericht heißt: Am Hahn ist kein Blei.","correction":"Der Prüfbericht gilt ab Wasserwerk. Blei kommt vor allem aus alten Bleirohren im Haus. Wasser aus Bleirohren ist laut Umweltbundesamt für Schwangere, Säuglinge und Kinder bis sechs Jahre immer ungeeignet; Filter oder eine Sanierung der Rohre helfen nicht, nur der vollständige Austausch.","source":{"title":"Umweltbundesamt: Trink Was – Trinkwasser aus dem Hahn (Ratgeber, 2020)","url":"https://www.umweltbundesamt.de/system/files/medien/421/publikationen/uba_trinkwas-ratgeber_2020-04-07_web_barrierefrei.pdf#page=16","page":"PDF-Seite 16"}}]}