Water hardness and tap water in Erzhausen
Landkreis Darmstadt-Dieburg, Hessen · Postcode 64390
This page is a translation of the German version; the German page is authoritative. German version · Report a translation error
- Limits of the Drinking Water OrdinancemetAll tested parameters (18), at the waterworks
- Water hardness19.1 °dH, hardNo legal limit, only a range
- Data coverageCore parameters: 7 of 7Score based on complete data
Verified drinking-water values
| Parameter | Value | Limit (TrinkwV) | Sampling date | Source | Status |
|---|---|---|---|---|---|
| Nitrate | 16.8 mg/L | 50 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Nitrite | < 0.03 mg/L | 0.5 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| PFAS (sum) | 0.002 µg/L | 0.1 µg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Lead | < 0.002 mg/L | 0.01 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Arsenic | < 0.002 mg/L | 0.01 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Uranium | 0.00605 mg/L | 0.01 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Mercury | < 0.000002 mg/L | 0.001 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Copper | < 0.03 mg/L | 2 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Cadmium | < 0.00005 mg/L | 0.003 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Chromium | < 0.001 mg/L | 0.025 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Nickel | < 0.001 mg/L | 0.02 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Chloride | 27 mg/L | 250 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Sulphate | 75.9 mg/L | 250 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Sodium | 11.7 mg/L | 200 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Calcium | 102.2 mg/L | – | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Magnesium | 17.6 mg/L | – | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| pH | 7.5 | 6.5–9.5 | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Total hardness | 19.1 °dH (hard) | no legal limit | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Electrical conductivity | 659 µS/cm | – | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Fluoride | < 0.1 mg/L | 1.5 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Ammonium | < 0.03 mg/L | 0.5 mg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Coliform bacteria | 0 KBE/100ml | 0 per 100 ml | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Trihalomethanes (THM) | < 15 µg/L | 50 µg/L | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Säurekapazität bis pH 4,3 | 4.55 mmol/L | – | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
| Hydrogencarbonat | 274 mg/L | – | 2025 | ENTEGA AG / Hessenwasser GmbH & Co. KG | verified |
Note from the test report (in the German original): ENTEGA AG · Die Analyse nennt Erzhausen nicht selbst. Laut BDEW-Wasserportal liegen der Gemeindemittelpunkt von Erzhausen und vier Prüfpunkte rund 1,5 km darum im selben Versorgungsgebiet wie Biebesheim am Rhein; deshalb stehen hier die Werte von Biebesheim am Rhein (Stand 31.12.2025), ab Wasserwerk. Einzelne Ortsteile können anderes Wasser bekommen; verbindlich ist die Auskunft des Versorgers.
Background on household plumbing, not a measurement: in Erzhausen, 40 % of buildings with living space were built before 1970, and a further 15 % between 1970 and 1979 (Zensus 2022, Statistisches Bundesamt, dl-de/by-2-0). (Zensus 2022) According to the German Environment Agency (Umweltbundesamt), lead pipes exist at most in houses built before 1973 – and by no means in all of them. Whether there are any in your house is known to the owner or a plumber. (UBA)
What the values mean for Erzhausen
- Nitrate 16.8 mg/L – about 34 % of the limit of 50 mg/L and in the medium range – such values occur in catchments shaped by agriculture. Boiling does not reduce nitrate.
- PFAS (sum of PFAS-20) 2 ng/L – about 2 % of the limit of 100 ng/L (since 12 January 2026).
- Lead – not detectable at the waterworks. Lead gets into the water almost only through old lead pipes in household plumbing, not via the supplier.
- Uranium 6.05 µg/L – within the checked range against a limit of 10 µg/L. In some regions uranium occurs naturally from the rock (geogenic).
- pH 7.5 – within the range of the Drinking Water Ordinance (6.5 to 9.5). The pH determines how corrosive the water is in household plumbing.
Water hardness in Erzhausen in everyday life
At 19.1 °dH, Erzhausen is in the hardness range “hard” (soft: below 8.4 °dH, medium: 8.4–14 °dH, hard: above 14 °dH).
- Dose detergent for the hardness range “hard” – a larger amount is needed; a water softener for the washing machine can save detergent.
- Limescale builds up quickly: descale the kettle about every two to three weeks, and taps and shower heads too.
- In your own house, limescale protection or a water softener can be worthwhile at this hardness; in a rented flat, the owner decides.
Baby food and low sodium: tap water in Erzhausen next to the bottled-water thresholds
Bottled water may only be labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) if it keeps to the maximum levels of the German Mineral and Table Water Ordinance (Mineral- und Tafelwasser-Verordnung, Annex 6). Here the published values for Erzhausen are shown next to them, each substance on its own. This is a comparison with labelling thresholds for bottled water, not a statement on whether your tap water is suitable for baby food. (Min/TafelWV, Anlage 6)
For context: the German Environment Agency (Umweltbundesamt) considers preparing baby food with bottled water carrying this label necessary only in rare cases, for example when tap water is temporarily allowed to contain more than 50 mg/l nitrate. (UBA 2016, p. 59) Water from lead pipes in the house is always unsuitable for infants. (UBA 2020, p. 16) The values apply at the waterworks.
| Substance | Maximum level | Value in Erzhausen |
|---|---|---|
| Sodium | 20 mg/l | 11.7 mg/l – not above |
| Nitrate | 10 mg/l | 16.8 mg/l – above the bottled-water threshold |
| Nitrite | 0.02 mg/l | below the detection limit (0.03 mg/l) – cannot be assessed |
| Sulphate | 240 mg/l | 75.9 mg/l – not above |
| Fluoride | 0.7 mg/l | below the detection limit (0.1 mg/l) – not above |
| Manganese | 0.05 mg/l | not in the report |
| Arsenic | 0.005 mg/l | below the detection limit (0.002 mg/l) – not above |
| Uranium | 0.002 mg/l | 0.00605 mg/l – above the bottled-water threshold |
Against the other thresholds of Annex 6, the water would qualify as: low in sodium (“suitable for a low-sodium diet”) (Sodium 11.7 mg/l, threshold below 20 mg/l).
Questions about baby food are answered by your midwife, your paediatrician and the health office (Gesundheitsamt).
Frequently asked questions about tap water in Erzhausen
Can you drink the tap water in Erzhausen?
According to the verified values, yes: All tested parameters with a legal limit (18) meet the limits set by the German Drinking Water Ordinance (TrinkwV). WaterScore: 98.8 out of 100 (data coverage: 7 of 7 core parameters). This applies to the water from the waterworks – restrictions can only arise from old household plumbing.
How hard is the water in Erzhausen?
The total hardness is 19.1 °dH – hardness range “hard”. Dose detergent for the hardness range “hard” – a larger amount is needed; a water softener for the washing machine can save detergent.
Is there PFAS in the tap water in Erzhausen?
Yes, in measurable amounts: according to the published analysis by ENTEGA AG (as of 2025), the sum of PFAS-20 is 0.002 (middle of the range given by the supplier) µg/l – that is 2 % of the limit of 0.1 µg/l, which has applied since 12 January 2026.
Do I need to filter my tap water in Erzhausen?
Based on the verified supplier values, a filter is not necessary. It can make sense if you do not like the taste. If you suspect lead pipes in an old building, a filter does not help; a laboratory analysis at the tap does – that is a question of the household plumbing, not of the water leaving the works.
WaterScore
- Total98.8 / 100
- Chemical safety93.9 / 100
- Heavy metals93.8 / 100
- PFAS100 / 100
- Nutrients100 / 100
- General parameters100 / 100
- Data timeliness100 / 100
- Data quality100 / 100
Data coverage: 7 of 7 core parameters. Missing parameters are neither estimated nor counted as harmless: the score is based only on the values available. It is not a health assessment and says nothing about the water beyond the service connection. Methodology v4: how we calculate the WaterScore.
Evidence: cite and check
- Trinkwasser Versorgungsgebiet Darmstadt – Analysenergebnisse, Mittelwerte 2025, Stand 2026 (ENTEGA AG / Hessenwasser GmbH & Co. KG) · SHA-256 of the evaluated file: 4594515b01ff08dd…, checked on 1 November 2026
Suggested citation: Trinkwassermonitor (2025): Tap water in Erzhausen. Values according to the water supplier’s test report, sampling date 2025; at the waterworks, not household plumbing. https://trinkwassermonitor.ink/en/tap-water/erzhausen/
JSON: /api/v1/evidence?city=erzhausen
Data as of: 2025 · verified: 25 of 25 evaluated parameters.
This page shows only verified test data with sources, or states explicitly where data is missing (no estimated values). Cite as: “Trinkwassermonitor (2026). Tap water in Erzhausen. Retrieved from https://trinkwassermonitor.ink/en/tap-water/erzhausen/.”