TrinkwassermonitorTap water in Germany

Water hardness and tap water in Horb am Neckar

Landkreis Freudenstadt, Baden-Württemberg · Postcode 72160

This page is a translation of the German version; the German page is authoritative. German version · Report a translation error

Short answer: The tap water in Horb am Neckar has a total hardness of 12.5 °dH, hardness range “medium” (as of 2026). All tested parameters with a legal limit (19) meet the limits set by the German Drinking Water Ordinance (TrinkwV). Source: test report by Stadtwerke Horb. WaterScore: 100 out of 100 (data coverage: 7 of 7 core parameters).

Verified drinking-water values

ParameterValueLimit (TrinkwV)Sampling dateSourceStatus
Nitrate20 mg/L
50 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Nitrite< 0.02 mg/L0.5 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
PFAS (sum)0.001 µg/L0.1 µg/L

2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Lead< 0.001 mg/L0.01 mg/L
2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Arsenic< 0.001 mg/L0.01 mg/L
2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Uranium< 0.001 mg/L0.01 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Mercury< 0.0001 mg/L0.001 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Copper< 0.005 mg/L2 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Cadmium< 0.0003 mg/L0.003 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Chromium< 0.0005 mg/L0.025 mg/L
2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Nickel< 0.002 mg/L0.02 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Chloride5 mg/L250 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Sulphate28 mg/L
250 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Sodium1.9 mg/L200 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Calcium72 mg/L–2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Magnesium11 mg/L–2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Total hardness12.5 °dH (medium)no legal limit2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Electrical conductivity451 µS/cm–2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Fluoride< 0.1 mg/L1.5 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Iron< 0.02 mg/L0.2 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Manganese< 0.005 mg/L0.05 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Ammonium< 0.05 mg/L0.5 mg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Coliform bacteria0 KBE/100ml0 per 100 ml2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified
Trihalomethanes (THM)6 µg/L
50 µg/L2026Stadtwerke Horb (veröffentlicht im BDEW-Wasserportal)verified

Note from the test report (in the German original): Stadtwerke Horb · Trinkwasseranalyse für das Versorgungsgebiet Stadtwerke Horb am Neckar - 2, Stand 2026, veröffentlicht im BDEW-Wasserportal. Die Werte wurden automatisch aus dem PDF ausgelesen und einzeln gegengeprüft; die Seite steht beim Originalwert. Laut Wasserportal liegen der Ortsmittelpunkt von Horb am Neckar und vier Prüfpunkte rund 1,5 km darum in diesem Versorgungsgebiet. Welches Wasser an einer bestimmten Adresse ankommt, sagt verbindlich der Versorger. Die Werte gelten ab Wasserwerk.

Is a value wrong or out of date? Report an error – we check every report against the original source.

Water at your own tap: The values describe the water the supplier delivers – not automatically the water at your tap. The water supplier is responsible up to the service connection (Hausanschluss); the building owner is responsible for the pipes beyond it. Lead can dissolve from lead pipes, leaded solder joints or old brass fittings, especially when water has stood in the pipes for a long time (stagnant water); this mainly affects buildings constructed before about 1973. If water has stood in the pipes for several hours, let it run until it comes out cool. If you suspect lead pipes, a lead analysis of the stagnant water by an accredited laboratory will help.

Background on household plumbing, not a measurement: in Horb am Neckar, 43 % of buildings with living space were built before 1970, and a further 15 % between 1970 and 1979 (Zensus 2022, Statistisches Bundesamt, dl-de/by-2-0). (Zensus 2022) According to the German Environment Agency (Umweltbundesamt), lead pipes exist at most in houses built before 1973 – and by no means in all of them. Whether there are any in your house is known to the owner or a plumber. (UBA)

What the values mean for Horb am Neckar

Water hardness in Horb am Neckar in everyday life

At 12.5 °dH, Horb am Neckar is in the hardness range “medium” (soft: below 8.4 °dH, medium: 8.4–14 °dH, hard: above 14 °dH).

Baby food and low sodium: tap water in Horb am Neckar next to the bottled-water thresholds

Bottled water may only be labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) if it keeps to the maximum levels of the German Mineral and Table Water Ordinance (Mineral- und Tafelwasser-Verordnung, Annex 6). Here the published values for Horb am Neckar are shown next to them, each substance on its own. This is a comparison with labelling thresholds for bottled water, not a statement on whether your tap water is suitable for baby food. (Min/TafelWV, Anlage 6)

Values at the waterworks next to the maximum levels for bottled water “suitable for infant food”
SubstanceMaximum levelValue in Horb am Neckar
Sodium20 mg/l1.9 mg/l – not above
Nitrate10 mg/l20 mg/l – above
Nitrite0.02 mg/lbelow the detection limit (0.02 mg/l) – not above
Sulphate240 mg/l28 mg/l – not above
Fluoride0.7 mg/lbelow the detection limit (0.1 mg/l) – not above
Manganese0.05 mg/lbelow the detection limit (0.005 mg/l) – not above
Arsenic0.005 mg/lbelow the detection limit (0.001 mg/l) – not above
Uranium0.002 mg/lbelow the detection limit (0.001 mg/l) – not above

Against the other thresholds of Annex 6, the water would qualify as: low in sodium (“suitable for a low-sodium diet”) (Sodium 1.9 mg/l, threshold below 20 mg/l).

For context: the German Environment Agency (Umweltbundesamt) considers preparing baby food with bottled water carrying this label necessary only in rare cases, for example when tap water is temporarily allowed to contain more than 50 mg/l nitrate. (UBA 2016, p. 59) Water from lead pipes in the house is always unsuitable for infants. (UBA 2020, p. 16) The values apply at the waterworks. Questions about baby food are answered by your midwife, your paediatrician and the health office (Gesundheitsamt).

Frequently asked questions about tap water in Horb am Neckar

Can you drink the tap water in Horb am Neckar?

According to the verified values, yes: All tested parameters with a legal limit (19) meet the limits set by the German Drinking Water Ordinance (TrinkwV). WaterScore: 100 out of 100 (data coverage: 7 of 7 core parameters). This applies to the water from the waterworks – restrictions can only arise from old household plumbing.

How hard is the water in Horb am Neckar?

The total hardness is 12.5 °dH – hardness range “medium”. Dose detergent for the hardness range “medium”.

Is there PFAS in the tap water in Horb am Neckar?

Yes, in measurable amounts: according to the published analysis by Stadtwerke Horb (as of 2026), the sum of PFAS-20 is 0.001 µg/l – that is 1 % of the limit of 0.1 µg/l, which has applied since 12 January 2026. Even this sum of all 20 substances is below the limit of 0.02 µg/l that applies from 12 January 2028 to the sum of four of them (PFAS-4).

Do I need to filter my tap water in Horb am Neckar?

Based on the verified supplier values, a filter is not necessary. It can make sense if you do not like the taste. If you suspect lead pipes in an old building, a filter does not help; a laboratory analysis at the tap does – that is a question of the household plumbing, not of the water leaving the works.

Is the nitrate level in Horb am Neckar a concern?

The value of 20 mg/L is below the limit of 50 mg/L, but higher than in many other evaluated cities. The limit of the Drinking Water Ordinance also applies to preparing baby food; mineral water labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) may contain at most 10 mg/L nitrate. Boiling does not help against nitrate.

WaterScore

Data coverage: 7 of 7 core parameters. Missing parameters are neither estimated nor counted as harmless: the score is based only on the values available. It is not a health assessment and says nothing about the water beyond the service connection. Methodology v3: how we calculate the WaterScore.

Evidence: cite and check

Suggested citation: Trinkwassermonitor (2026): Tap water in Horb am Neckar. Values according to the water supplier’s test report, sampling date 2026; at the waterworks, not household plumbing. https://trinkwassermonitor.ink/en/tap-water/horb-am-neckar/

JSON: /api/v1/evidence?city=horb-am-neckar

Data as of: 2026 · verified: 24 of 24 evaluated parameters.

This page shows only verified test data with sources, or states explicitly where data is missing (no estimated values). Cite as: “Trinkwassermonitor (2026). Tap water in Horb am Neckar. Retrieved from https://trinkwassermonitor.ink/en/tap-water/horb-am-neckar/.”

Further information