Short answer: The tap water in Kempten (Allgäu) has a total hardness of 12.6 °dH, hardness range “medium” (as of 30 June 2026). All tested parameters with a legal limit (16) meet the limits set by the German Drinking Water Ordinance (TrinkwV). Source: test report by Kemptener Kommunalunternehmen (KKU). WaterScore: 100 out of 100 (data coverage: 7 of 7 core parameters).

Verified drinking-water values

ParameterValueLimit (TrinkwV)Sampling dateSourceStatus
Nitrate2.4 mg/L50 mg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Nitrite< 0.01 mg/L0.5 mg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
PFAS (sum)< 0.001 µg/L0.1 µg/L

30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Lead< 0.002 mg/L0.01 mg/L
30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Arsenic< 0.001 mg/L0.01 mg/L
30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Uranium< 0.001 mg/L0.01 mg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Mercury< 0.0001 mg/L0.001 mg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Copper< 0.005 mg/L2 mg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Chloride9 mg/L250 mg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Sulphate19.8 mg/L250 mg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Sodium5.1 mg/L200 mg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Calcium71.3 mg/L–30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Magnesium12 mg/L–30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
pH7.766.5–9.530 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Total hardness12.6 °dH (medium)no legal limit30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Electrical conductivity447 µS/cm–30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Fluoride< 0.25 mg/L1.5 mg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Iron< 0.01 mg/L0.2 mg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Manganese< 0.005 mg/L0.05 mg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Ammonium0.01 mg/L0.5 mg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified
Trihalomethanes (THM)below the limit of quantification50 µg/L30 June 2026Kemptener Kommunalunternehmen (KKU); Labor Dr. Feierabend GmbH, Überlingen (DAkkS D-PL19137-02-00)verified

Note from the test report (in the German original): Zone Mittel-/Niederzone (Cambomare) deckt den Großteil der Stadt inkl. Zentrum ab und wird hier als Stadtwert verwendet; die Speisung ist ein Mix aus ca. 80% Zweckverband Fernwasserversorgung Oberes Allgäu und ca. 20% städtischen Quellen (Fleschützen, Leubas). KKU veröffentlicht daneben eine zweite, deutlich härtere Zone St. Mang/Lenzfried/Leubas (19,9 °dH/hart statt 12,6 °dH/mittel, Leitfähigkeit 711 statt 447 µS/cm) – bewusst nicht vermischt, siehe eigener Prüfbericht (Analyse_SM_(2)_30.06.2026.pdf). Ein dritter, kleiner Versorger (Wasserbeschaffungsverband Hirschdorf) beliefert einige Randweiler und wurde nicht recherchiert. Der Bericht deckt nur TrinkwV-Gruppe-B-Parameter ab; Coliforme/E. coli (Gruppe A, Mikrobiologie) sind darin nicht enthalten und wurden nirgends sonst öffentlich gefunden. Die Summe-Trihalogenmethane-Zeile ist im Originalbericht als 'mg/l' beschriftet, was angesichts der µg/l-Einzelkongenerwerte und des Grenzwerts 50 ein Einheiten-Tippfehler im Laborbericht zu sein scheint – hier als µg/L geführt, Wert ist ohnehin n.n. (nicht nachweisbar).

Is a value wrong or out of date? Report an error – we check every report against the original source.

Water at your own tap: The values describe the water the supplier delivers – not automatically the water at your tap. The water supplier is responsible up to the service connection (Hausanschluss); the building owner is responsible for the pipes beyond it. Lead can dissolve from lead pipes, leaded solder joints or old brass fittings, especially when water has stood in the pipes for a long time (stagnant water); this mainly affects buildings constructed before about 1973. If water has stood in the pipes for several hours, let it run until it comes out cool. If you suspect lead pipes, a lead analysis of the stagnant water by an accredited laboratory will help.

Background on household plumbing, not a measurement: in Kempten (Allgäu), 48 % of buildings with living space were built before 1970, and a further 12 % between 1970 and 1979 (Zensus 2022, Statistisches Bundesamt, dl-de/by-2-0). (Zensus 2022) According to the German Environment Agency (Umweltbundesamt), lead pipes exist at most in houses built before 1973 – and by no means in all of them. Whether there are any in your house is known to the owner or a plumber. (UBA)

What the values mean for Kempten (Allgäu)

Water hardness in Kempten (Allgäu) in everyday life

At 12.6 °dH, Kempten (Allgäu) is in the hardness range “medium” (soft: below 8.4 °dH, medium: 8.4–14 °dH, hard: above 14 °dH).

Baby food and low sodium: tap water in Kempten (Allgäu) next to the bottled-water thresholds

Bottled water may only be labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) if it keeps to the maximum levels of the German Mineral and Table Water Ordinance (Mineral- und Tafelwasser-Verordnung, Annex 6). Here the published values for Kempten (Allgäu) are shown next to them, each substance on its own. This is a comparison with labelling thresholds for bottled water, not a statement on whether your tap water is suitable for baby food. (Min/TafelWV, Anlage 6)

Values at the waterworks next to the maximum levels for bottled water “suitable for infant food”
SubstanceMaximum levelValue in Kempten (Allgäu)
Sodium20 mg/l5.1 mg/l – not above
Nitrate10 mg/l2.4 mg/l – not above
Nitrite0.02 mg/lbelow the detection limit (0.01 mg/l) – not above
Sulphate240 mg/l19.8 mg/l – not above
Fluoride0.7 mg/lbelow the detection limit (0.25 mg/l) – not above
Manganese0.05 mg/lbelow the detection limit (0.005 mg/l) – not above
Arsenic0.005 mg/lbelow the detection limit (0.001 mg/l) – not above
Uranium0.002 mg/lbelow the detection limit (0.001 mg/l) – not above

Against the other thresholds of Annex 6, the water would qualify as: low in sodium (“suitable for a low-sodium diet”) (Sodium 5.1 mg/l, threshold below 20 mg/l).

For context: the German Environment Agency (Umweltbundesamt) considers preparing baby food with bottled water carrying this label necessary only in rare cases, for example when tap water is temporarily allowed to contain more than 50 mg/l nitrate. (UBA 2016, p. 59) Water from lead pipes in the house is always unsuitable for infants. (UBA 2020, p. 16) The values apply at the waterworks. Questions about baby food are answered by your midwife, your paediatrician and the health office (Gesundheitsamt).

Frequently asked questions about tap water in Kempten (Allgäu)

Can you drink the tap water in Kempten (Allgäu)?

According to the verified values, yes: All tested parameters with a legal limit (16) meet the limits set by the German Drinking Water Ordinance (TrinkwV). WaterScore: 100 out of 100 (data coverage: 7 of 7 core parameters). This applies to the water from the waterworks – restrictions can only arise from old household plumbing.

How hard is the water in Kempten (Allgäu)?

The total hardness is 12.6 °dH – hardness range “medium”. Dose detergent for the hardness range “medium”.

Is there PFAS in the tap water in Kempten (Allgäu)?

Not in measurable amounts: according to the published analysis by Kemptener Kommunalunternehmen (KKU) (as of 30 June 2026), PFAS were below the laboratory’s limit of quantification. Since 12 January 2026, a limit of 0.1 µg/l has applied to the sum of PFAS-20. This means the sum of the four substances PFOA, PFOS, PFNA and PFHxS (PFAS-4) is also below the limit of 0.02 µg/l, which applies from 12 January 2028.

Do I need to filter my tap water in Kempten (Allgäu)?

Based on the verified supplier values, a filter is not necessary. It can make sense if you do not like the taste. If you suspect lead pipes in an old building, a filter does not help; a laboratory analysis at the tap does – that is a question of the household plumbing, not of the water leaving the works.

WaterScore

Data coverage: 7 of 7 core parameters. Missing parameters are neither estimated nor counted as harmless: the score is based only on the values available. It is not a health assessment and says nothing about the water beyond the service connection. Methodology v3: how we calculate the WaterScore.

Evidence: cite and check

Suggested citation: Trinkwassermonitor (2026): Tap water in Kempten (Allgäu). Values according to the water supplier’s test report, sampling date 30 June 2026; at the waterworks, not household plumbing. https://trinkwassermonitor.ink/en/tap-water/kempten/

JSON: /api/v1/evidence?city=kempten

Data as of: 30 June 2026 · verified: 21 of 21 evaluated parameters.

This page shows only verified test data with sources, or states explicitly where data is missing (no estimated values). Cite as: “Trinkwassermonitor (2026). Tap water in Kempten (Allgäu). Retrieved from https://trinkwassermonitor.ink/en/tap-water/kempten/.”