TrinkwassermonitorTap water in Germany

Water hardness and tap water in Mörfelden-Walldorf

Landkreis Groß-Gerau, Hessen · Postcode 64546

This page is a translation of the German version; the German page is authoritative. German version · Report a translation error

Short answer: Depending on the address, Mörfelden-Walldorf receives water from two supply zones: Wasserwerk Mörfelden at 12.9 °dH and Wasserwerk Walldorf at 12.8 °dH, both in the hardness range “medium” (as of 17 March 2025). All tested parameters with a legal limit (34) meet the limits set by the German Drinking Water Ordinance (TrinkwV). Source: test report by Stadtwerke Mörfelden-Walldorf. WaterScore: 97.6 out of 100 (data coverage: 5 of 7 core parameters).
two waters depending on the district: The values above apply to the water “Wasserwerk Mörfelden”, according to the supplier for laut Stadtwerken eines von zwei beprobten Wasserwerken; welche Adressen es beliefert, veröffentlichen sie nicht. Other waters: “Wasserwerk Walldorf”. The supplier does not publish how many addresses each water supplies.

Verified drinking-water values: water “Wasserwerk Mörfelden”

ParameterValueLimit (TrinkwV)Sampling dateSourceStatus
Nitrate0.5 mg/L50 mg/L17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Nitrite< 0.02 mg/L0.5 mg/L
17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Lead< 0.001 mg/L0.01 mg/L
17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Arsenic< 0.001 mg/L0.01 mg/L
17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Mercury< 0.00005 mg/L0.001 mg/L17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Copper< 0.005 mg/L2 mg/L17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Cadmium< 0.0005 mg/L0.003 mg/L17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Chromium< 0.0005 mg/L0.025 mg/L
17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Nickel< 0.002 mg/L0.02 mg/L17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Chloride44.4 mg/L
250 mg/L17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Sulphate96 mg/L
250 mg/L17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Sodium19.2 mg/L200 mg/L17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Calcium78.6 mg/L–17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Magnesium8.21 mg/L–17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
pH7.626.5–9.517 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Total hardness12.9 °dH (medium)no legal limit17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Fluoride< 0.2 mg/L1.5 mg/L17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Iron< 0.01 mg/L0.2 mg/L17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Manganese< 0.005 mg/L0.05 mg/L17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified
Ammonium0.05 mg/L
0.5 mg/L17 March 2025Stadtwerke Mörfelden-Walldorf (Analyse: Labor Fresenius, Taunusstein)verified

Note from the test report (in the German original): Stadtwerke Mörfelden-Walldorf · Ausgewählte Inhaltsstoffe, Trinkwasseruntersuchung 2025 (Labor Fresenius). Diese Werte gelten für das Wasserwerk Mörfelden, Probe vom 17.03.2025. Die Stadtwerke veröffentlichen beide Wasserwerke getrennt, aber nicht, welches Werk welche Adresse beliefert; die Werte unterscheiden sich vor allem beim Nitrat deutlich. Auskunft geben die Stadtwerke. PFAS nennt diese Übersicht nicht.

Is a value wrong or out of date? Report an error – we check every report against the original source.

Water at your own tap: The values describe the water the supplier delivers – not automatically the water at your tap. The water supplier is responsible up to the service connection (Hausanschluss); the building owner is responsible for the pipes beyond it. Lead can dissolve from lead pipes, leaded solder joints or old brass fittings, especially when water has stood in the pipes for a long time (stagnant water); this mainly affects buildings constructed before about 1973. If water has stood in the pipes for several hours, let it run until it comes out cool. If you suspect lead pipes, a lead analysis of the stagnant water by an accredited laboratory will help.

Background on household plumbing, not a measurement: in Mörfelden-Walldorf, 54 % of buildings with living space were built before 1970, and a further 19 % between 1970 and 1979 (Zensus 2022, Statistisches Bundesamt, dl-de/by-2-0). (Zensus 2022) According to the German Environment Agency (Umweltbundesamt), lead pipes exist at most in houses built before 1973 – and by no means in all of them. Whether there are any in your house is known to the owner or a plumber. (UBA)

What the values mean for Mörfelden-Walldorf

Water hardness in Mörfelden-Walldorf in everyday life

At 12.9 °dH, Mörfelden-Walldorf is in the hardness range “medium” (soft: below 8.4 °dH, medium: 8.4–14 °dH, hard: above 14 °dH).

Baby food and low sodium: tap water in Mörfelden-Walldorf next to the bottled-water thresholds

Bottled water may only be labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) if it keeps to the maximum levels of the German Mineral and Table Water Ordinance (Mineral- und Tafelwasser-Verordnung, Annex 6). Here the published values for Mörfelden-Walldorf are shown next to them, each substance on its own. This is a comparison with labelling thresholds for bottled water, not a statement on whether your tap water is suitable for baby food. (Min/TafelWV, Anlage 6)

For context: the German Environment Agency (Umweltbundesamt) considers preparing baby food with bottled water carrying this label necessary only in rare cases, for example when tap water is temporarily allowed to contain more than 50 mg/l nitrate. (UBA 2016, p. 59) Water from lead pipes in the house is always unsuitable for infants. (UBA 2020, p. 16) The values apply at the waterworks.

Values at the waterworks next to the maximum levels for bottled water “suitable for infant food”
SubstanceMaximum levelValue in Mörfelden-Walldorf
Sodium20 mg/l19.2 mg/l – not above
Nitrate10 mg/l0.5 mg/l – not above
Nitrite0.02 mg/lbelow the detection limit (0.02 mg/l) – not above
Sulphate240 mg/l96 mg/l – not above
Fluoride0.7 mg/lbelow the detection limit (0.2 mg/l) – not above
Manganese0.05 mg/lbelow the detection limit (0.005 mg/l) – not above
Arsenic0.005 mg/lbelow the detection limit (0.001 mg/l) – not above
Uranium0.002 mg/lnot in the report

Against the other thresholds of Annex 6, the water would qualify as: low in sodium (“suitable for a low-sodium diet”) (Sodium 19.2 mg/l, threshold below 20 mg/l).

Questions about baby food are answered by your midwife, your paediatrician and the health office (Gesundheitsamt).

Frequently asked questions about tap water in Mörfelden-Walldorf

Can you drink the tap water in Mörfelden-Walldorf?

According to the verified values, yes: All tested parameters with a legal limit (34) meet the limits set by the German Drinking Water Ordinance (TrinkwV). WaterScore: 97.6 out of 100 (data coverage: 5 of 7 core parameters). This applies to the water from the waterworks – restrictions can only arise from old household plumbing.

How hard is the water in Mörfelden-Walldorf?

It depends on the address: Wasserwerk Mörfelden 12.9 °dH and Wasserwerk Walldorf 12.8 °dH – both in the hardness range “medium”. Dose detergent for the hardness range “medium”.

Is there PFAS in the tap water in Mörfelden-Walldorf?

The published analysis by Stadtwerke Mörfelden-Walldorf that we evaluated gives no PFAS value. This does not mean there is no PFAS in the water; there is simply no figure for it. Since 12 January 2026, a limit of 0.1 µg/l has applied to the sum of PFAS-20. The supplier can tell you whether PFAS was measured and with what result. For the other waters, the analyses give no PFAS value.

Do I need to filter my tap water in Mörfelden-Walldorf?

Based on the verified supplier values, a filter is not necessary. It can make sense if you do not like the taste. If you suspect lead pipes in an old building, a filter does not help; a laboratory analysis at the tap does – that is a question of the household plumbing, not of the water leaving the works.

Is the nitrate level in Mörfelden-Walldorf a concern?

It depends on the address: Wasserwerk Mörfelden 0.5 mg/L and Wasserwerk Walldorf 29 mg/L. All values are below the limit of 50 mg/L. The limit of the Drinking Water Ordinance also applies to preparing baby food; mineral water labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) may contain at most 10 mg/L nitrate. Boiling does not help against nitrate.

WaterScore

Data coverage: 5 of 7 core parameters. Not in the test report: Uranium and PFAS (sum). Missing parameters are neither estimated nor counted as harmless: the score is based only on the values available. It is not a health assessment and says nothing about the water beyond the service connection. Methodology v4: how we calculate the WaterScore.

Evidence: cite and check

Suggested citation: Trinkwassermonitor (2025): Tap water in Mörfelden-Walldorf. Values according to the water supplier’s test report, sampling date 17 March 2025; at the waterworks, not household plumbing. https://trinkwassermonitor.ink/en/tap-water/moerfelden-walldorf/

JSON: /api/v1/evidence?city=moerfelden-walldorf

Data as of: 17 March 2025 · verified: 20 of 20 evaluated parameters. (older than twelve months – under § 46 TrinkwV your supplier must publish current values online)

This page shows only verified test data with sources, or states explicitly where data is missing (no estimated values). Cite as: “Trinkwassermonitor (2026). Tap water in Mörfelden-Walldorf. Retrieved from https://trinkwassermonitor.ink/en/tap-water/moerfelden-walldorf/.”

Further information