TrinkwassermonitorTap water in Germany

Water hardness and tap water in Rheine

Kreis Steinfurt, Nordrhein-Westfalen · Postcode 48429, 48431, 48432

This page is a translation of the German version; the German page is authoritative. German version · Report a translation error

Short answer: The tap water in Rheine has a total hardness of 9.58 °dH, hardness range “medium” (as of 14 April 2026). All tested parameters with a legal limit (14) meet the limits set by the German Drinking Water Ordinance (TrinkwV). Source: test report by Energie- und Wasserversorgung Rheine (EWR). WaterScore: 100 out of 100 (data coverage: 5 of 7 core parameters).

Verified drinking-water values

ParameterValueLimit (TrinkwV)Sampling dateSourceStatus
Nitrate4.8 mg/L50 mg/L14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Nitrite< 0.03 mg/L0.5 mg/L14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
PFAS (sum)0.0069 µg/L0.1 µg/L

14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
PFOA0.0027 µg/L–14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
PFOS< 0.001 µg/L–14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
PFHxS0.0012 µg/L–14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
PFBS0.0013 µg/L–14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Lead< 0.002 mg/L0.01 mg/L
14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Arsenic< 0.0025 mg/L0.01 mg/L
14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Mercury< 0.0001 mg/L0.001 mg/L14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Chloride32 mg/L
250 mg/L14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Sulphate63 mg/L
250 mg/L14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Sodium18.6 mg/L200 mg/L14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Calcium56.1 mg/L–14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Magnesium7.34 mg/L–14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
pH7.526.5–9.514 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Total hardness9.58 °dH (medium)no legal limit14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Electrical conductivity459 µS/cm–14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Fluoride< 0.1 mg/L1.5 mg/L14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Iron< 0.04 mg/L0.2 mg/L14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Manganese< 0.03 mg/L0.05 mg/L14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Ammonium< 0.1 mg/L0.5 mg/L14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified
Coliform bacteria0 KBE/100ml0 per 100 ml14 April 2026Universitätsklinikum Münster, Institut für Hygiene (DAkkS-akkreditiert), im Auftrag der Energie- und Wasserversorgung Rheine GmbHverified

Note from the test report (in the German original): Einzelprobe vom 14.04.2026 am Reinwasser des Wasserwerks St. Arnold, das laut Analysekarte der Stadtwerke den Großteil des Stadtgebiets versorgt (u. a. Innenstadt, Dorenkamp, Eschendorf, Mesum). Nördliche und nordöstliche Bereiche erhalten Wasser aus dem Wasserwerk Hemelter Bach, das am 16.04.2026 mit 14,0 °dH (2,48 mmol/l) knapp unter der Grenze zum Härtebereich hart lag. Welches Werk Ihre Straße versorgt, zeigt die Analysekarte auf stadtwerke-rheine.de. Kupfer, Uran und Trihalogenmethane sind in diesen Berichten nicht ausgewiesen.

Is a value wrong or out of date? Report an error – we check every report against the original source.

Water at your own tap: The values describe the water the supplier delivers – not automatically the water at your tap. The water supplier is responsible up to the service connection (Hausanschluss); the building owner is responsible for the pipes beyond it. Lead can dissolve from lead pipes, leaded solder joints or old brass fittings, especially when water has stood in the pipes for a long time (stagnant water); this mainly affects buildings constructed before about 1973. If water has stood in the pipes for several hours, let it run until it comes out cool. If you suspect lead pipes, a lead analysis of the stagnant water by an accredited laboratory will help.

Background on household plumbing, not a measurement: in Rheine, 43 % of buildings with living space were built before 1970, and a further 13 % between 1970 and 1979 (Zensus 2022, Statistisches Bundesamt, dl-de/by-2-0). (Zensus 2022) According to the German Environment Agency (Umweltbundesamt), lead pipes exist at most in houses built before 1973 – and by no means in all of them. Whether there are any in your house is known to the owner or a plumber. (UBA)

What the values mean for Rheine

Water hardness in Rheine in everyday life

At 9.58 °dH, Rheine is in the hardness range “medium” (soft: below 8.4 °dH, medium: 8.4–14 °dH, hard: above 14 °dH).

Baby food and low sodium: tap water in Rheine next to the bottled-water thresholds

Bottled water may only be labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) if it keeps to the maximum levels of the German Mineral and Table Water Ordinance (Mineral- und Tafelwasser-Verordnung, Annex 6). Here the published values for Rheine are shown next to them, each substance on its own. This is a comparison with labelling thresholds for bottled water, not a statement on whether your tap water is suitable for baby food. (Min/TafelWV, Anlage 6)

Values at the waterworks next to the maximum levels for bottled water “suitable for infant food”
SubstanceMaximum levelValue in Rheine
Sodium20 mg/l18.6 mg/l – not above
Nitrate10 mg/l4.8 mg/l – not above
Nitrite0.02 mg/lbelow the detection limit (0.03 mg/l) – cannot be assessed
Sulphate240 mg/l63 mg/l – not above
Fluoride0.7 mg/lbelow the detection limit (0.1 mg/l) – not above
Manganese0.05 mg/lbelow the detection limit (0.03 mg/l) – not above
Arsenic0.005 mg/lbelow the detection limit (0.0025 mg/l) – not above
Uranium0.002 mg/lnot in the report

Against the other thresholds of Annex 6, the water would qualify as: low in sodium (“suitable for a low-sodium diet”) (Sodium 18.6 mg/l, threshold below 20 mg/l).

For context: the German Environment Agency (Umweltbundesamt) considers preparing baby food with bottled water carrying this label necessary only in rare cases, for example when tap water is temporarily allowed to contain more than 50 mg/l nitrate. (UBA 2016, p. 59) Water from lead pipes in the house is always unsuitable for infants. (UBA 2020, p. 16) The values apply at the waterworks. Questions about baby food are answered by your midwife, your paediatrician and the health office (Gesundheitsamt).

Frequently asked questions about tap water in Rheine

Can you drink the tap water in Rheine?

According to the verified values, yes: All tested parameters with a legal limit (14) meet the limits set by the German Drinking Water Ordinance (TrinkwV). WaterScore: 100 out of 100 (data coverage: 5 of 7 core parameters). This applies to the water from the waterworks – restrictions can only arise from old household plumbing.

How hard is the water in Rheine?

The total hardness is 9.58 °dH – hardness range “medium”. Dose detergent for the hardness range “medium”.

Is there PFAS in the tap water in Rheine?

Yes, in measurable amounts: according to the published analysis by Energie- und Wasserversorgung Rheine (EWR) (as of 14 April 2026), the sum of PFAS-20 is 0.0069 µg/l – that is 7 % of the limit of 0.1 µg/l, which has applied since 12 January 2026. Even this sum of all 20 substances is below the limit of 0.02 µg/l that applies from 12 January 2028 to the sum of four of them (PFAS-4).

Do I need to filter my tap water in Rheine?

Based on the verified supplier values, a filter is not necessary. It can make sense if you do not like the taste. If you suspect lead pipes in an old building, a filter does not help; a laboratory analysis at the tap does – that is a question of the household plumbing, not of the water leaving the works.

WaterScore

Data coverage: 5 of 7 core parameters. Not in the test report: Copper and Uranium. Missing parameters are neither estimated nor counted as harmless: the score is based only on the values available. It is not a health assessment and says nothing about the water beyond the service connection. Methodology v3: how we calculate the WaterScore.

Evidence: cite and check

Suggested citation: Trinkwassermonitor (2026): Tap water in Rheine. Values according to the water supplier’s test report, sampling date 14 April 2026; at the waterworks, not household plumbing. https://trinkwassermonitor.ink/en/tap-water/rheine/

JSON: /api/v1/evidence?city=rheine

Data as of: 14 April 2026 · verified: 23 of 23 evaluated parameters.

This page shows only verified test data with sources, or states explicitly where data is missing (no estimated values). Cite as: “Trinkwassermonitor (2026). Tap water in Rheine. Retrieved from https://trinkwassermonitor.ink/en/tap-water/rheine/.”

Further information