TrinkwassermonitorTap water in Germany

Water hardness and tap water in St. Egidien

Landkreis Zwickau, Sachsen · Postcode 09356

This page is a translation of the German version; the German page is authoritative. German version · Report a translation error

Short answer: The tap water in St. Egidien has a total hardness of 3.3 °dH, hardness range “soft” (as of 6 March 2026). All tested parameters with a legal limit (20) meet the limits set by the German Drinking Water Ordinance (TrinkwV). Source: test report by RZV Lugau-Glauchau. WaterScore: 100 out of 100 (data coverage: 7 of 7 core parameters).

Verified drinking-water values

ParameterValueLimit (TrinkwV)Sampling dateSourceStatus
Nitrate2.7 mg/L50 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Nitrite< 0.01 mg/L0.5 mg/L
6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
PFAS (sum)< 0.0015 µg/L0.1 µg/L

6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Lead< 0.001 mg/L0.01 mg/L
6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Arsenic< 0.001 mg/L0.01 mg/L
6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Uranium0.00023 mg/L0.01 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Mercury< 0.0001 mg/L0.001 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Copper0.0063 mg/L2 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Cadmium< 0.0001 mg/L0.003 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Chromium0.00121 mg/L0.025 mg/L
6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Nickel< 0.001 mg/L0.02 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Chloride17.3 mg/L250 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Sulphate12 mg/L250 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Sodium11.3 mg/L200 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Calcium21.1 mg/L–6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Magnesium1.58 mg/L–6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
pH86.5–9.56 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Total hardness3.3 °dH (soft)no legal limit6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Electrical conductivity180 µS/cm–6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Fluoride0.19 mg/L
1.5 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Iron< 0.01 mg/L0.2 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Manganese0.003 mg/L0.05 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Ammonium< 0.02 mg/L0.5 mg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified
Trihalomethanes (THM)4.8 µg/L50 µg/L6 March 2026Regionaler Zweckverband Wasserversorgung Bereich Lugau-Glauchauverified

Note from the test report (in the German original): Prüfbericht des RZV Lugau-Glauchau, Probenahme am 06.03.2026 (St. Egidien, Evang.-Luth. Pfarrhaus). Der Verband ordnet diesen Bericht in seiner adressgenauen Abfrage der Versorgungszone Bernsdorf OT Rüsdorf, St. Egidien HB St. Egidien, St. Egidien OT Kuhschnappel, St. Egidien OT Lobsdorf zu – rund 90 % der Adressen, die der Verband in St. Egidien versorgt. Die übrigen Adressen (rund 10 %) hängen an anderen Versorgungszonen. PFAS (Summe PFAS-20 und PFAS-4) lagen unter der Bestimmungsgrenze. Der Bericht enthält keine mikrobiologischen Werte. Welches Wasser an einer bestimmten Adresse ankommt, zeigt die Abfrage auf rzv-glauchau.de; Ortsteile, die die Abfrage nicht führt, versorgt der Verband dort nicht.

Is a value wrong or out of date? Report an error – we check every report against the original source.

Water at your own tap: The values describe the water the supplier delivers – not automatically the water at your tap. The water supplier is responsible up to the service connection (Hausanschluss); the building owner is responsible for the pipes beyond it. Lead can dissolve from lead pipes, leaded solder joints or old brass fittings, especially when water has stood in the pipes for a long time (stagnant water); this mainly affects buildings constructed before about 1973. If water has stood in the pipes for several hours, let it run until it comes out cool. If you suspect lead pipes, a lead analysis of the stagnant water by an accredited laboratory will help.

Background on household plumbing, not a measurement: in St. Egidien, 63 % of buildings with living space were built before 1970, and a further 3 % between 1970 and 1979 (Zensus 2022, Statistisches Bundesamt, dl-de/by-2-0). (Zensus 2022) According to the German Environment Agency (Umweltbundesamt), lead pipes exist at most in houses built before 1973 – and by no means in all of them. Whether there are any in your house is known to the owner or a plumber. (UBA)

What the values mean for St. Egidien

Water hardness in St. Egidien in everyday life

At 3.3 °dH, St. Egidien is in the hardness range “soft” (soft: below 8.4 °dH, medium: 8.4–14 °dH, hard: above 14 °dH).

Baby food and low sodium: tap water in St. Egidien next to the bottled-water thresholds

Bottled water may only be labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) if it keeps to the maximum levels of the German Mineral and Table Water Ordinance (Mineral- und Tafelwasser-Verordnung, Annex 6). Here the published values for St. Egidien are shown next to them, each substance on its own. This is a comparison with labelling thresholds for bottled water, not a statement on whether your tap water is suitable for baby food. (Min/TafelWV, Anlage 6)

For context: the German Environment Agency (Umweltbundesamt) considers preparing baby food with bottled water carrying this label necessary only in rare cases, for example when tap water is temporarily allowed to contain more than 50 mg/l nitrate. (UBA 2016, p. 59) Water from lead pipes in the house is always unsuitable for infants. (UBA 2020, p. 16) The values apply at the waterworks.

Values at the waterworks next to the maximum levels for bottled water “suitable for infant food”
SubstanceMaximum levelValue in St. Egidien
Sodium20 mg/l11.3 mg/l – not above
Nitrate10 mg/l2.7 mg/l – not above
Nitrite0.02 mg/lbelow the detection limit (0.01 mg/l) – not above
Sulphate240 mg/l12 mg/l – not above
Fluoride0.7 mg/l0.19 mg/l – not above
Manganese0.05 mg/l0.003 mg/l – not above
Arsenic0.005 mg/lbelow the detection limit (0.001 mg/l) – not above
Uranium0.002 mg/l0.00023 mg/l – not above

Against the other thresholds of Annex 6, the water would qualify as: low in sodium (“suitable for a low-sodium diet”) (Sodium 11.3 mg/l, threshold below 20 mg/l).

Questions about baby food are answered by your midwife, your paediatrician and the health office (Gesundheitsamt).

Frequently asked questions about tap water in St. Egidien

Can you drink the tap water in St. Egidien?

According to the verified values, yes: All tested parameters with a legal limit (20) meet the limits set by the German Drinking Water Ordinance (TrinkwV). WaterScore: 100 out of 100 (data coverage: 7 of 7 core parameters). This applies to the water from the waterworks – restrictions can only arise from old household plumbing.

How hard is the water in St. Egidien?

The total hardness is 3.3 °dH – hardness range “soft”. Dose detergent for the hardness range “soft” – the lowest amount on the pack.

Is there PFAS in the tap water in St. Egidien?

Not in measurable amounts: according to the published analysis by RZV Lugau-Glauchau (as of 6 March 2026), PFAS were below the laboratory’s limit of quantification. Since 12 January 2026, a limit of 0.1 µg/l has applied to the sum of PFAS-20. This means the sum of the four substances PFOA, PFOS, PFNA and PFHxS (PFAS-4) is also below the limit of 0.02 µg/l, which applies from 12 January 2028.

Do I need to filter my tap water in St. Egidien?

Based on the verified supplier values, a filter is not necessary. It can make sense if you do not like the taste. If you suspect lead pipes in an old building, a filter does not help; a laboratory analysis at the tap does – that is a question of the household plumbing, not of the water leaving the works.

WaterScore

Data coverage: 7 of 7 core parameters. Missing parameters are neither estimated nor counted as harmless: the score is based only on the values available. It is not a health assessment and says nothing about the water beyond the service connection. Methodology v4: how we calculate the WaterScore.

Evidence: cite and check

Suggested citation: Trinkwassermonitor (2026): Tap water in St. Egidien. Values according to the water supplier’s test report, sampling date 6 March 2026; at the waterworks, not household plumbing. https://trinkwassermonitor.ink/en/tap-water/st-egidien/

JSON: /api/v1/evidence?city=st-egidien

Data as of: 6 March 2026 · verified: 24 of 24 evaluated parameters.

This page shows only verified test data with sources, or states explicitly where data is missing (no estimated values). Cite as: “Trinkwassermonitor (2026). Tap water in St. Egidien. Retrieved from https://trinkwassermonitor.ink/en/tap-water/st-egidien/.”

Further information