Water hardness and tap water in Stuttgart Feuerbach
Stuttgart, Baden-Württemberg · Postcode 70192, 70469
This page is a translation of the German version; the German page is authoritative. German version · Report a translation error
- Limits of the Drinking Water OrdinancemetAll tested parameters (18), at the waterworks
- Water hardness13.3 °dH, mediumNo legal limit, only a range
- Data coverageCore parameters: 5 of 7Score based on complete data
Verified drinking-water values
Note from the test report (in the German original): Netze BW Wasser GmbH · Trinkwasseranalyse für das Versorgungsgebiet Landeswasser , Stand 2025, veröffentlicht im BDEW-Wasserportal. Die Werte wurden automatisch aus dem PDF ausgelesen und einzeln gegengeprüft; die Seite steht beim Originalwert. Laut Wasserportal liegen der Ortsmittelpunkt von Stuttgart Feuerbach und vier Prüfpunkte rund 1,5 km darum in diesem Versorgungsgebiet. Welches Wasser an einer bestimmten Adresse ankommt, sagt verbindlich der Versorger. Die Werte gelten ab Wasserwerk.
What the values mean for Stuttgart Feuerbach
- Nitrate 22 mg/L – about 44 % of the limit of 50 mg/L and comparatively high for a city waterworks; the cause is usually nitrate from agriculture entering the raw water. Boiling does not reduce nitrate.
- Lead – not detectable at the waterworks. Lead gets into the water almost only through old lead pipes in household plumbing, not via the supplier.
- pH 7.6 – within the range of the Drinking Water Ordinance (6.5 to 9.5). The pH determines how corrosive the water is in household plumbing.
Water hardness in Stuttgart Feuerbach in everyday life
At 13.3 °dH, Stuttgart Feuerbach is in the hardness range “medium” (soft: below 8.4 °dH, medium: 8.4–14 °dH, hard: above 14 °dH).
- Dose detergent for the hardness range “medium”.
- As a rule of thumb, descale the kettle about every four to six weeks and the coffee machine as the manufacturer recommends.
- A limescale protection device is not a must at medium hardness; regular descaling is often enough.
Baby food and low sodium: tap water in Stuttgart Feuerbach next to the bottled-water thresholds
Bottled water may only be labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) if it keeps to the maximum levels of the German Mineral and Table Water Ordinance (Mineral- und Tafelwasser-Verordnung, Annex 6). Here the published values for Stuttgart Feuerbach are shown next to them, each substance on its own. This is a comparison with labelling thresholds for bottled water, not a statement on whether your tap water is suitable for baby food. (Min/TafelWV, Anlage 6)
| Substance | Maximum level | Value in Stuttgart Feuerbach |
|---|---|---|
| Sodium | 20 mg/l | 13 mg/l – not above |
| Nitrate | 10 mg/l | 22 mg/l – above |
| Nitrite | 0.02 mg/l | below the detection limit (0.01 mg/l) – not above |
| Sulphate | 240 mg/l | 21 mg/l – not above |
| Fluoride | 0.7 mg/l | below the detection limit (0.05 mg/l) – not above |
| Manganese | 0.05 mg/l | below the detection limit (0.005 mg/l) – not above |
| Arsenic | 0.005 mg/l | below the detection limit (0.001 mg/l) – not above |
| Uranium | 0.002 mg/l | not in the report |
Against the other thresholds of Annex 6, the water would qualify as: low in sodium (“suitable for a low-sodium diet”) (Sodium 13 mg/l, threshold below 20 mg/l).
For context: the German Environment Agency (Umweltbundesamt) considers preparing baby food with bottled water carrying this label necessary only in rare cases, for example when tap water is temporarily allowed to contain more than 50 mg/l nitrate. (UBA 2016, p. 59) Water from lead pipes in the house is always unsuitable for infants. (UBA 2020, p. 16) The values apply at the waterworks. Questions about baby food are answered by your midwife, your paediatrician and the health office (Gesundheitsamt).
Frequently asked questions about tap water in Stuttgart Feuerbach
Can you drink the tap water in Stuttgart Feuerbach?
According to the verified values, yes: All tested parameters with a legal limit (18) meet the limits set by the German Drinking Water Ordinance (TrinkwV). WaterScore: 100 out of 100 (data coverage: 5 of 7 core parameters). This applies to the water from the waterworks – restrictions can only arise from old household plumbing.
How hard is the water in Stuttgart Feuerbach?
The total hardness is 13.3 °dH – hardness range “medium”. Dose detergent for the hardness range “medium”.
Is there PFAS in the tap water in Stuttgart Feuerbach?
The published analysis by Netze BW Wasser GmbH that we evaluated gives no PFAS value. This does not mean there is no PFAS in the water; there is simply no figure for it. Since 12 January 2026, a limit of 0.1 µg/l has applied to the sum of PFAS-20. The supplier can tell you whether PFAS was measured and with what result.
Do I need to filter my tap water in Stuttgart Feuerbach?
Based on the verified supplier values, a filter is not necessary. It can make sense if you do not like the taste. If you suspect lead pipes in an old building, a filter does not help; a laboratory analysis at the tap does – that is a question of the household plumbing, not of the water leaving the works.
Is the nitrate level in Stuttgart Feuerbach a concern?
The value of 22 mg/L is below the limit of 50 mg/L, but higher than in many other evaluated cities. The limit of the Drinking Water Ordinance also applies to preparing baby food; mineral water labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) may contain at most 10 mg/L nitrate. Boiling does not help against nitrate.
WaterScore
- Total100 / 100
- Chemical safety100 / 100
- Heavy metals100 / 100
- Nutrients100 / 100
- General parameters100 / 100
- Data timeliness100 / 100
- Data quality100 / 100
Data coverage: 5 of 7 core parameters. Not in the test report: Uranium and PFAS (sum). Missing parameters are neither estimated nor counted as harmless: the score is based only on the values available. It is not a health assessment and says nothing about the water beyond the service connection. Methodology v3: how we calculate the WaterScore.
Evidence: cite and check
- Trinkwasseranalyse Versorgungsgebiet Landeswasser , Stand 2025 (Netze BW Wasser GmbH (veröffentlicht im BDEW-Wasserportal)) · SHA-256 of the evaluated file: 2604447a4fb7b3e4…, checked on 11 October 2026
Suggested citation: Trinkwassermonitor (2025): Tap water in Stuttgart Feuerbach. Values according to the water supplier’s test report, sampling date 2025; at the waterworks, not household plumbing. https://trinkwassermonitor.ink/en/tap-water/stuttgart-feuerbach/
JSON: /api/v1/evidence?city=stuttgart-feuerbach
Data as of: 2025 · verified: 23 of 23 evaluated parameters.