Water hardness and tap water in Tautenburg
Saale-Holzland-Kreis, Thüringen · Postcode 07778
This page is a translation of the German version; the German page is authoritative. German version · Report a translation error
- Limits of the Drinking Water OrdinancemetAll tested parameters (7), at the waterworks
- Water hardness15.8 °dH, hardNo legal limit, only a range
- Data coverageCore parameters: 3 of 7Score provisional
Verified drinking-water values
| Parameter | Value | Limit (TrinkwV) | Sampling date | Source | Status |
|---|---|---|---|---|---|
| Nitrate | 11 mg/L | 50 mg/L | 1 December 2025 | Zweckverband JenaWasser | verified |
| Nitrite | below the limit of quantification | 0.5 mg/L | 1 December 2025 | Zweckverband JenaWasser | verified |
| Uranium | 0.002 mg/L | 0.01 mg/L | 1 December 2025 | Zweckverband JenaWasser | verified |
| Chloride | 18 mg/L | 250 mg/L | 1 December 2025 | Zweckverband JenaWasser | verified |
| Sulphate | 65 mg/L | 250 mg/L | 1 December 2025 | Zweckverband JenaWasser | verified |
| Sodium | 5.6 mg/L | 200 mg/L | 1 December 2025 | Zweckverband JenaWasser | verified |
| Calcium | 76 mg/L | – | 1 December 2025 | Zweckverband JenaWasser | verified |
| Magnesium | 17 mg/L | – | 1 December 2025 | Zweckverband JenaWasser | verified |
| pH | 7.8 | 6.5–9.5 | 1 December 2025 | Zweckverband JenaWasser | verified |
| Total hardness | 15.8 °dH (hard) | no legal limit | 1 December 2025 | Zweckverband JenaWasser | verified |
| Electrical conductivity | 588 µS/cm | – | 1 December 2025 | Zweckverband JenaWasser | verified |
| Fluoride | below the limit of quantification | 1.5 mg/L | 1 December 2025 | Zweckverband JenaWasser | verified |
| Iron | 0.016 mg/L | 0.2 mg/L | 1 December 2025 | Zweckverband JenaWasser | verified |
| Manganese | below the limit of quantification | 0.05 mg/L | 1 December 2025 | Zweckverband JenaWasser | verified |
| Ammonium | below the limit of quantification | 0.5 mg/L | 1 December 2025 | Zweckverband JenaWasser | verified |
| Coliform bacteria | 0 KBE/100ml | 0 per 100 ml | 1 December 2025 | Zweckverband JenaWasser | verified |
Note from the test report (in the German original): JenaWasser · Übersicht „Trinkwasserbeschaffenheit“ des Zweckverbands JenaWasser, Stand 1. Dezember 2025. Laut Übersicht erhält Tautenburg Trinkwasser aus: Bezug Zweckverband Eisenberg (Wasserwerk Ullrichsberg). Ein Probenahmedatum nennt die Übersicht nicht; sie enthält eine Auswahl von Parametern ohne Blei, Arsen, Kupfer, Nickel, Cadmium, Chrom, Quecksilber und PFAS.
Background on household plumbing, not a measurement: in Tautenburg, 65 % of buildings with living space were built before 1970, and a further 6 % between 1970 and 1979 (Zensus 2022, Statistisches Bundesamt, dl-de/by-2-0). (Zensus 2022) According to the German Environment Agency (Umweltbundesamt), lead pipes exist at most in houses built before 1973 – and by no means in all of them. Whether there are any in your house is known to the owner or a plumber. (UBA)
What the values mean for Tautenburg
- Nitrate 11 mg/L – about 22 % of the limit of 50 mg/L and in the medium range – such values occur in catchments shaped by agriculture. Boiling does not reduce nitrate.
- Uranium 2 µg/L – within the checked range against a limit of 10 µg/L. In some regions uranium occurs naturally from the rock (geogenic).
- pH 7.8 – within the range of the Drinking Water Ordinance (6.5 to 9.5). The pH determines how corrosive the water is in household plumbing.
Water hardness in Tautenburg in everyday life
At 15.8 °dH, Tautenburg is in the hardness range “hard” (soft: below 8.4 °dH, medium: 8.4–14 °dH, hard: above 14 °dH).
- Dose detergent for the hardness range “hard” – a larger amount is needed; a water softener for the washing machine can save detergent.
- Limescale builds up quickly: descale the kettle about every two to three weeks, and taps and shower heads too.
- In your own house, limescale protection or a water softener can be worthwhile at this hardness; in a rented flat, the owner decides.
Baby food and low sodium: tap water in Tautenburg next to the bottled-water thresholds
Bottled water may only be labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) if it keeps to the maximum levels of the German Mineral and Table Water Ordinance (Mineral- und Tafelwasser-Verordnung, Annex 6). Here the published values for Tautenburg are shown next to them, each substance on its own. This is a comparison with labelling thresholds for bottled water, not a statement on whether your tap water is suitable for baby food. (Min/TafelWV, Anlage 6)
| Substance | Maximum level | Value in Tautenburg |
|---|---|---|
| Sodium | 20 mg/l | 5.6 mg/l – not above |
| Nitrate | 10 mg/l | 11 mg/l – above |
| Nitrite | 0.02 mg/l | below the limit of quantification – cannot be assessed |
| Sulphate | 240 mg/l | 65 mg/l – not above |
| Fluoride | 0.7 mg/l | below the limit of quantification – cannot be assessed |
| Manganese | 0.05 mg/l | below the limit of quantification – cannot be assessed |
| Arsenic | 0.005 mg/l | not in the report |
| Uranium | 0.002 mg/l | 0.002 mg/l – not above |
Against the other thresholds of Annex 6, the water would qualify as: low in sodium (“suitable for a low-sodium diet”) (Sodium 5.6 mg/l, threshold below 20 mg/l).
For context: the German Environment Agency (Umweltbundesamt) considers preparing baby food with bottled water carrying this label necessary only in rare cases, for example when tap water is temporarily allowed to contain more than 50 mg/l nitrate. (UBA 2016, p. 59) Water from lead pipes in the house is always unsuitable for infants. (UBA 2020, p. 16) The values apply at the waterworks. Questions about baby food are answered by your midwife, your paediatrician and the health office (Gesundheitsamt).
Frequently asked questions about tap water in Tautenburg
Can you drink the tap water in Tautenburg?
According to the verified values, yes: All tested parameters with a legal limit (7) meet the limits set by the German Drinking Water Ordinance (TrinkwV). WaterScore (provisional): 100 out of 100 – the test report contains only 3 of 7 core parameters. This applies to the water from the waterworks – restrictions can only arise from old household plumbing.
How hard is the water in Tautenburg?
The total hardness is 15.8 °dH – hardness range “hard”. Dose detergent for the hardness range “hard” – a larger amount is needed; a water softener for the washing machine can save detergent.
Is there PFAS in the tap water in Tautenburg?
The published analysis by JenaWasser that we evaluated gives no PFAS value. This does not mean there is no PFAS in the water; there is simply no figure for it. Since 12 January 2026, a limit of 0.1 µg/l has applied to the sum of PFAS-20. The supplier can tell you whether PFAS was measured and with what result.
Do I need to filter my tap water in Tautenburg?
Based on the verified supplier values, a filter is not necessary. It can make sense if you do not like the taste. If you suspect lead pipes in an old building, a filter does not help; a laboratory analysis at the tap does – that is a question of the household plumbing, not of the water leaving the works.
WaterScore
- Total (provisional)100 / 100
- Chemical safety100 / 100
- Heavy metals100 / 100
- Nutrients100 / 100
- General parameters100 / 100
- Data timeliness100 / 100
- Data quality100 / 100
Data coverage: 3 of 7 core parameters. Not in the test report: Lead, Copper, Arsenic and PFAS (sum). Missing parameters are neither estimated nor counted as harmless: the score is based only on the values available and is therefore provisional. It is not a health assessment and says nothing about the water beyond the service connection. Methodology v3: how we calculate the WaterScore.
Evidence: cite and check
- Trinkwasserbeschaffenheit und eingesetzte Aufbereitungsstoffe/Desinfektionsverfahren im Verbandsgebiet des Zweckverbandes JenaWasser, Stand 1. Dezember 2025 (Zweckverband JenaWasser) · SHA-256 of the evaluated file: 0c63739534e0b95c…, checked on 3 October 2026
Suggested citation: Trinkwassermonitor (2025): Tap water in Tautenburg. Values according to the water supplier’s test report, sampling date 1 December 2025; at the waterworks, not household plumbing. https://trinkwassermonitor.ink/en/tap-water/tautenburg/
JSON: /api/v1/evidence?city=tautenburg
Data as of: 1 December 2025 · verified: 16 of 16 evaluated parameters.
This page shows only verified test data with sources, or states explicitly where data is missing (no estimated values). Cite as: “Trinkwassermonitor (2026). Tap water in Tautenburg. Retrieved from https://trinkwassermonitor.ink/en/tap-water/tautenburg/.”