Water hardness and tap water in Vendersheim
Landkreis Alzey-Worms, Rheinland-Pfalz · Postcode 55578
This page is a translation of the German version; the German page is authoritative. German version · Report a translation error
- Limits of the Drinking Water OrdinancemetAll tested parameters (19), at the waterworks
- Water hardness21.1 °dH, hardNo legal limit, only a range
- Data coverageCore parameters: 7 of 7Score based on complete data
Verified drinking-water values
| Parameter | Value | Limit (TrinkwV) | Sampling date | Source | Status |
|---|---|---|---|---|---|
| Nitrate | 30 mg/L | 50 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Nitrite | < 0.02 mg/L | 0.5 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| PFAS (sum) | 0.01 µg/L | 0.1 µg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| PFOA | < 0.001 µg/L | – | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| PFOS | < 0.001 µg/L | – | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| PFHxS | 0.002 µg/L | – | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| PFBS | 0.002 µg/L | – | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| TFA (Trifluoressigsäure) | 2.2 µg/L | – | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| PFNA | < 0.001 µg/L | – | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Lead | < 0.001 mg/L | 0.01 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Arsenic | < 0.001 mg/L | 0.01 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Uranium | 0.0055 mg/L | 0.01 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Mercury | < 0.00005 mg/L | 0.001 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Copper | 0.016 mg/L | 2 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Cadmium | < 0.0005 mg/L | 0.003 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Chromium | < 0.0005 mg/L | 0.025 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Nickel | < 0.002 mg/L | 0.02 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Chloride | 76.8 mg/L | 250 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Sulphate | 106 mg/L | 250 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Sodium | 36.6 mg/L | 200 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Calcium | 120 mg/L | – | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Magnesium | 18.7 mg/L | – | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| pH | 7.52 | 6.5–9.5 | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Total hardness | 21.1 °dH (hard) | no legal limit | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Electrical conductivity | 922 µS/cm | – | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Fluoride | < 0.2 mg/L | 1.5 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Iron | < 0.01 mg/L | 0.2 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Manganese | < 0.005 mg/L | 0.05 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Ammonium | < 0.04 mg/L | 0.5 mg/L | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Coliform bacteria | 0 KBE/100ml | 0 per 100 ml | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
| Säurekapazität bis pH 4,3 | 4.45 mmol/L | – | 11 March 2026 | Wasserversorgung Rheinhessen-Pfalz GmbH | verified |
Note from the test report (in the German original): Wasserversorgung Rheinhessen-Pfalz GmbH · Prüfbericht Nr. 7985097 (freigegeben 30.04.2026), Versorgungsgebiet Wasserwerk Ingelheim. Auf ihrer Karte der Wasseranalysen ordnet die WVR Vendersheim diesem Bericht zu. Die Probe stammt vom 11.03.2026 aus dem Ortsnetz in Engelstadt (Kindergarten Raiffeisenstraße 9, Küche, Hahn Handwaschbecken), nicht aus Vendersheim selbst und nicht ab Wasserwerk; die Hausinstallation ist nicht erfasst. Es ist eine Einzelprobe. Trihalogenmethane bildet der Bericht nicht als Summe, deshalb fehlt dieser Wert hier.
Background on household plumbing, not a measurement: in Vendersheim, 34 % of buildings with living space were built before 1970, and a further 12 % between 1970 and 1979 (Zensus 2022, Statistisches Bundesamt, dl-de/by-2-0). (Zensus 2022) According to the German Environment Agency (Umweltbundesamt), lead pipes exist at most in houses built before 1973 – and by no means in all of them. Whether there are any in your house is known to the owner or a plumber. (UBA)
What the values mean for Vendersheim
- Nitrate 30 mg/L – about 60 % of the limit of 50 mg/L and comparatively high for a city waterworks; the cause is usually nitrate from agriculture entering the raw water. Boiling does not reduce nitrate.
- PFAS (sum of PFAS-20) 10 ng/L – about 10 % of the limit of 100 ng/L (since 12 January 2026).
- Lead – not detectable at the waterworks. Lead gets into the water almost only through old lead pipes in household plumbing, not via the supplier.
- Uranium 5.5 µg/L – within the checked range against a limit of 10 µg/L. In some regions uranium occurs naturally from the rock (geogenic).
- pH 7.52 – within the range of the Drinking Water Ordinance (6.5 to 9.5). The pH determines how corrosive the water is in household plumbing.
Water hardness in Vendersheim in everyday life
At 21.1 °dH, Vendersheim is in the hardness range “hard” (soft: below 8.4 °dH, medium: 8.4–14 °dH, hard: above 14 °dH).
- Dose detergent for the hardness range “hard” – a larger amount is needed; a water softener for the washing machine can save detergent.
- Limescale builds up quickly: descale the kettle about every two to three weeks, and taps and shower heads too.
- In your own house, limescale protection or a water softener can be worthwhile at this hardness; in a rented flat, the owner decides.
Baby food and low sodium: tap water in Vendersheim next to the bottled-water thresholds
Bottled water may only be labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) if it keeps to the maximum levels of the German Mineral and Table Water Ordinance (Mineral- und Tafelwasser-Verordnung, Annex 6). Here the published values for Vendersheim are shown next to them, each substance on its own. This is a comparison with labelling thresholds for bottled water, not a statement on whether your tap water is suitable for baby food. (Min/TafelWV, Anlage 6)
For context: the German Environment Agency (Umweltbundesamt) considers preparing baby food with bottled water carrying this label necessary only in rare cases, for example when tap water is temporarily allowed to contain more than 50 mg/l nitrate. (UBA 2016, p. 59) Water from lead pipes in the house is always unsuitable for infants. (UBA 2020, p. 16) The values apply at the waterworks.
| Substance | Maximum level | Value in Vendersheim |
|---|---|---|
| Sodium | 20 mg/l | 36.6 mg/l – above the bottled-water threshold |
| Nitrate | 10 mg/l | 30 mg/l – above the bottled-water threshold |
| Nitrite | 0.02 mg/l | below the detection limit (0.02 mg/l) – not above |
| Sulphate | 240 mg/l | 106 mg/l – not above |
| Fluoride | 0.7 mg/l | below the detection limit (0.2 mg/l) – not above |
| Manganese | 0.05 mg/l | below the detection limit (0.005 mg/l) – not above |
| Arsenic | 0.005 mg/l | below the detection limit (0.001 mg/l) – not above |
| Uranium | 0.002 mg/l | 0.0055 mg/l – above the bottled-water threshold |
Questions about baby food are answered by your midwife, your paediatrician and the health office (Gesundheitsamt).
Frequently asked questions about tap water in Vendersheim
Can you drink the tap water in Vendersheim?
According to the verified values, yes: All tested parameters with a legal limit (19) meet the limits set by the German Drinking Water Ordinance (TrinkwV). WaterScore: 98.4 out of 100 (data coverage: 7 of 7 core parameters). This applies to the water from the waterworks – restrictions can only arise from old household plumbing.
How hard is the water in Vendersheim?
The total hardness is 21.1 °dH – hardness range “hard”. Dose detergent for the hardness range “hard” – a larger amount is needed; a water softener for the washing machine can save detergent.
Is there PFAS in the tap water in Vendersheim?
Yes, in measurable amounts: according to the published analysis by Wasserversorgung Rheinhessen-Pfalz (WVR) (as of 11 March 2026), the sum of PFAS-20 is 0.01 µg/l – that is 10 % of the limit of 0.1 µg/l, which has applied since 12 January 2026. Even this sum of all 20 substances is below the limit of 0.02 µg/l that applies from 12 January 2028 to the sum of four of them (PFAS-4).
Do I need to filter my tap water in Vendersheim?
Based on the verified supplier values, a filter is not necessary. It can make sense if you do not like the taste. If you suspect lead pipes in an old building, a filter does not help; a laboratory analysis at the tap does – that is a question of the household plumbing, not of the water leaving the works.
Is the nitrate level in Vendersheim a concern?
The value of 30 mg/L is below the limit of 50 mg/L, but higher than in many other evaluated cities. The limit of the Drinking Water Ordinance also applies to preparing baby food; mineral water labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) may contain at most 10 mg/L nitrate. Boiling does not help against nitrate.
WaterScore
- Total98.4 / 100
- Chemical safety94.1 / 100
- Heavy metals97 / 100
- PFAS100 / 100
- Nutrients93.6 / 100
- General parameters100 / 100
- Data timeliness100 / 100
- Data quality100 / 100
Data coverage: 7 of 7 core parameters. Missing parameters are neither estimated nor counted as harmless: the score is based only on the values available. It is not a health assessment and says nothing about the water beyond the service connection. Methodology v4: how we calculate the WaterScore.
Evidence: cite and check
- Prüfbericht Nr. 7985097, Versorgungsgebiet Wasserwerk Ingelheim, Probe im Ortsnetz Engelstadt vom 11.03.2026 (Wasserversorgung Rheinhessen-Pfalz GmbH) · SHA-256 of the evaluated file: a872edbd40e6a0c4…, checked on 28 October 2026
Suggested citation: Trinkwassermonitor (2026): Tap water in Vendersheim. Values according to the water supplier’s test report, sampling date 11 March 2026; at the waterworks, not household plumbing. https://trinkwassermonitor.ink/en/tap-water/vendersheim/
JSON: /api/v1/evidence?city=vendersheim
Data as of: 11 March 2026 · verified: 31 of 31 evaluated parameters.