Water hardness and tap water in Chemnitz
Chemnitz, Sachsen · Postcode 09111, 09112, 09113, 09114, 09116, 09117 …
This page is a translation of the German version; the German page is authoritative. German version · Report a translation error
- Limits of the Drinking Water OrdinancemetAll tested parameters (17), at the waterworks
- Water hardness4.7 °dH, softNo legal limit, only a range
- Data coverageCore parameters: 7 of 7Score based on complete data
Verified drinking-water values
Note from the test report (in the German original): Chemnitz wird aus zwei Versorgungsbereichen versorgt: 'Wasserwerk Einsiedel' (reines Einsiedel-Wasser, u.a. für Einsiedel, Zentrum, Schloßchemnitz) und 'Mischwasser aus den Wasserwerken Burkersdorf/Einsiedel' (u.a. Adelsberg, Rabenstein). Diese Werte gelten nur für den Einsiedel-Bereich (inkl. Zentrum); der Mischwasser-Bereich hat leicht abweichende Werte (z. B. Nitrat 6,7 statt 12 mg/l, Härte 4,2 statt 4,7 °dH, Fluorid 0,11 statt 0,084 mg/l) und ist als separates Dokument bei eins.de verfügbar. Der Bericht trägt den Titel 'Jahresauswertung 2025' ohne exaktes Tagesdatum; alle Werte sind Mittelwerte aus Minimum/Maximum/Mittelwert-Tabellen. Bei mit 'unter Bestimmungsgrenze' markierten Stoffen lag der Mittelwert unterhalb der Bestimmungsgrenze, auch wenn Einzelmessungen (Maximum) leicht darüber lagen (z. B. Nitrit Max 0,011 mg/l, Trihalogenmethane Max 0,0054 mg/l = 5,4 µg/l, Kupfer Max 0,0012 mg/l). PFAS wird nur als Summenparameter berichtet, keine Einzelsubstanzen (PFOA/PFOS/PFHxS/PFBS nicht separat ausgewiesen).
Background on household plumbing, not a measurement: in Chemnitz, 57 % of buildings with living space were built before 1970, and a further 7 % between 1970 and 1979 (Zensus 2022, Statistisches Bundesamt, dl-de/by-2-0). (Zensus 2022) According to the German Environment Agency (Umweltbundesamt), lead pipes exist at most in houses built before 1973 – and by no means in all of them. Whether there are any in your house is known to the owner or a plumber. (UBA)
What the values mean for Chemnitz
- Nitrate 12 mg/L – about 24 % of the limit of 50 mg/L and in the medium range – such values occur in catchments shaped by agriculture. Boiling does not reduce nitrate.
- PFAS (sum of PFAS-20) – not detectable in the sample evaluated. The limit of 0.1 µg/L (100 ng/L) has applied since 12 January 2026.
- Lead – not detectable at the waterworks. Lead gets into the water almost only through old lead pipes in household plumbing, not via the supplier.
- Uranium – not detectable at the waterworks (limit 10 µg/L).
- pH 8 – within the range of the Drinking Water Ordinance (6.5 to 9.5). The pH determines how corrosive the water is in household plumbing.
Water hardness in Chemnitz in everyday life
At 4.7 °dH, Chemnitz is in the hardness range “soft” (soft: below 8.4 °dH, medium: 8.4–14 °dH, hard: above 14 °dH).
- Dose detergent for the hardness range “soft” – the lowest amount on the pack.
- Limescale deposits are rare; kettles and coffee machines only need descaling every few months.
- At this hardness you do not need limescale protection or a water softener.
Baby food and low sodium: tap water in Chemnitz next to the bottled-water thresholds
Bottled water may only be labelled “suitable for preparing infant food” („geeignet für die Zubereitung von Säuglingsnahrung“) if it keeps to the maximum levels of the German Mineral and Table Water Ordinance (Mineral- und Tafelwasser-Verordnung, Annex 6). Here the published values for Chemnitz are shown next to them, each substance on its own. This is a comparison with labelling thresholds for bottled water, not a statement on whether your tap water is suitable for baby food. (Min/TafelWV, Anlage 6)
| Substance | Maximum level | Value in Chemnitz |
|---|---|---|
| Sodium | 20 mg/l | 10.4 mg/l – not above |
| Nitrate | 10 mg/l | 12 mg/l – above |
| Nitrite | 0.02 mg/l | below the detection limit (0.01 mg/l) – not above |
| Sulphate | 240 mg/l | 30 mg/l – not above |
| Fluoride | 0.7 mg/l | 0.084 mg/l – not above |
| Manganese | 0.05 mg/l | 0.003 mg/l – not above |
| Arsenic | 0.005 mg/l | below the detection limit (0.001 mg/l) – not above |
| Uranium | 0.002 mg/l | below the detection limit (0.0001 mg/l) – not above |
Against the other thresholds of Annex 6, the water would qualify as: low in sodium (“suitable for a low-sodium diet”) (Sodium 10.4 mg/l, threshold below 20 mg/l).
For context: the German Environment Agency (Umweltbundesamt) considers preparing baby food with bottled water carrying this label necessary only in rare cases, for example when tap water is temporarily allowed to contain more than 50 mg/l nitrate. (UBA 2016, p. 59) Water from lead pipes in the house is always unsuitable for infants. (UBA 2020, p. 16) The values apply at the waterworks. Questions about baby food are answered by your midwife, your paediatrician and the health office (Gesundheitsamt).
Frequently asked questions about tap water in Chemnitz
Can you drink the tap water in Chemnitz?
According to the verified values, yes: All tested parameters with a legal limit (17) meet the limits set by the German Drinking Water Ordinance (TrinkwV). WaterScore: 100 out of 100 (data coverage: 7 of 7 core parameters). This applies to the water from the waterworks – restrictions can only arise from old household plumbing.
How hard is the water in Chemnitz?
The total hardness is 4.7 °dH – hardness range “soft”. Dose detergent for the hardness range “soft” – the lowest amount on the pack.
Is there PFAS in the tap water in Chemnitz?
Not in measurable amounts: according to the published analysis by eins energie in sachsen (as of 2025), PFAS were below the laboratory’s limit of quantification. Since 12 January 2026, a limit of 0.1 µg/l has applied to the sum of PFAS-20.
Do I need to filter my tap water in Chemnitz?
Based on the verified supplier values, a filter is not necessary. It can make sense if you do not like the taste. If you suspect lead pipes in an old building, a filter does not help; a laboratory analysis at the tap does – that is a question of the household plumbing, not of the water leaving the works.
WaterScore
- Total100 / 100
- Chemical safety100 / 100
- Heavy metals100 / 100
- PFAS100 / 100
- Nutrients100 / 100
- General parameters100 / 100
- Data timeliness100 / 100
- Data quality100 / 100
Data coverage: 7 of 7 core parameters. Missing parameters are neither estimated nor counted as harmless: the score is based only on the values available. It is not a health assessment and says nothing about the water beyond the service connection. Methodology v3: how we calculate the WaterScore.
Evidence: cite and check
- Trinkwasser Jahresauswertung 2025 – Wasserwerk Einsiedel (Südsachsen Wasser GmbH (Zweckverband Fernwasser Südsachsen), Labor Wasserwerk Einsiedel – veröffentlicht über eins energie in sachsen) · SHA-256 of the evaluated file: e0917bc09825eca8…, checked on 3 October 2026
Suggested citation: Trinkwassermonitor (2025): Tap water in Chemnitz. Values according to the water supplier’s test report, sampling date 2025; at the waterworks, not household plumbing. https://trinkwassermonitor.ink/en/tap-water/chemnitz/
JSON: /api/v1/evidence?city=chemnitz
Data as of: 2025 · verified: 22 of 22 evaluated parameters.
This page shows only verified test data with sources, or states explicitly where data is missing (no estimated values). Cite as: “Trinkwassermonitor (2026). Tap water in Chemnitz. Retrieved from https://trinkwassermonitor.ink/en/tap-water/chemnitz/.”